6. ELECTRICAL DATA
6-1. Electrical Characteristics
COOLING
Model Number : STW0622C2 / 0623C2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 2.22 / 2.44 2.7 / 2.9
Power input kW 0.025 / 0.020 0.085 / 0.075 0.500 / 0.505 0.61 / 0.60
Full load conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 2.82 / 3.04 3.3 / 3.5
Power input kW 0.025 / 0.020 0.085 / 0.075 0.630 / 0.635 0.74 / 0.73
Model Number : STW0922C2 / 0923C2 / 0925C2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 3.02 / 3.34 3.5 / 3.8
Power input kW 0.025 / 0.020 0.085 / 0.075 0.690 / 0.685 0.80 / 0.78
Full load conditions Running amps. A 0.11 / 0.10 0.37 / 0.36 3.82 / 4.14 4.3 / 4.6
Power input kW 0.025 / 0.020 0.085 / 0.075 0.870 / 0.855 0.98 / 0.95
Model Number : STW1222C2 / 1223C2 / 1225C2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 4.30 / 4.80 4.9 / 5.4
Power input kW 0.040 / 0.035 0.100 / 0.090 0.960 / 0.965 1.10 / 1.09
Full load conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 5.50 / 6.20 6.1 / 6.8
Power input kW 0.040 / 0.035 0.100 / 0.090 1.240 / 1.235 1.38 / 1.36
Model Number : STW1522C2 /1523C2 / 1525C2
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V, 1-phase 60Hz
Rating conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 6.30 / 6.60 6.9 / 7.2
Power input kW 0.040 / 0.035 0.100 / 0.090 1.350 / 1.335 1.49 / 1.46
Full load conditions Running amps. A 0.17 / 0.17 0.43 / 0.43 8.00 / 8.40 8.6 / 9.0
Power input kW 0.040 / 0.035 0.100 / 0.090 1.720 / 1.705 1.86 / 1.83
Rating Conditions : Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 115°F (46.1°C) D.B.
Cooling & electric heating models (230/208 V)