50
Turn on the scale:
Press e/[ON/OFF]
> All display segments light up
briefly
Select the over/under
checkweighing application in the
Setup menu: Press M
Select menu:
Press the menu soft key
(w/[TOGGLE])
Set parameter 2 1 8:
See “Configuring the Scale”
Exit the Setup menu:
Press M
Setting Parameters for the Over/
Under Checkweighing Application
k Access the Setup menu:
Select Menu
Set parameters for:
Automatic initialization when
scale switched on:
3 10 auto-start app.
Automatic printout when
weight value is within limits
and scale at stability:
4 2 auto print +/-
Control lines on:
4 3 +/- ctrl ports on
Automatic output of
initialization values to
interface port:
7 1 Print app. param.
Signal direction for data output
port lines:
8 8 1 input or
8 8 2 output
See “Configuring the Scale”
Exit the Setup menu:
Press M
Additional Functions
In addition to functions for:
alphanumeric input
(not during initialization),
taring
(not during alphanumeric input),
printing,
you can also access the following
functions from this application:
calibration
(not during alphanumeric input
or during initialization),
setup (not during initialization),
turning off the scale.
Calibration/Adjustment
Press [ISOTEST]/[TEST]
> See “Calibration/Adjustment”
for further instructions
Setup (setting parameters)
Press M
> See “Configuring the Scale” for
further instructions
Turning Off the Scale
Press e/[ON/OFF]
> The scale shuts off
> The display goes blank

Related product manuals