23
Operating the Scale
Operating the Scale
Basic Weighing Function
Purpose
The basic weighing function
is always accessible and can be
used alone or in combination with
an application program (Toggle
between Weight Units, Counting,
Weighing in Percent, etc.).
Features
Taring the scale
Assigning IDs to weights
Printing weights
Printing ID codes for weights
Factory Settings
Tare: After stability (1 5 2)
Print manual/automatic:
Manual after stability (6 1 2)
Line format for printout:
For other applications/GLP (7 2 2)
Alphanumeric input of a weight ID:
Keys unblocked (8 3 1)
Under-Scale Weighing
A port for a under-scale
weighing hanger is located on the
bottom of the scale.
FB… BBE, FB… CCE:
Open cover plate (1) on the
bottom of the scale
Attach the sample (e.g., using a
suspension wire) to the hook (2).
FBG… EDE:
Use a suitable screwdriver to
remove the cover plate from the
bottom of the scale.
Fasten the hook to the cross
(see “Accessories”).
k If necessary, install a shield for
protection against drafts
Important Note Concerning
Verified Scales Approved
for Use as Legal Measuring
Instruments in the EU*:
The under-scale weighing port
may not be opened or used when
an approved scale is being
operated as a legal measuring
instrument.
* including the Signatories
of the Agreement on the European
Economic Area
Preparation
Turn on the scale:
Press e/[ON/OFF]
> All display segments light up
briefly
k To change configurations:
see the chapter entitled
“Configuring the Scale”
k To load factory-set configurations:
see “Configuring the Scale,”
parameter 9 1
k To tare the scale: Press t
> The U symbol is displayed
when the scale is zeroed or tared
(only on scales verified* for use in
legal metrology; ±0,5 digit))
Using Verified Scales Approved
for Use as Legal Measuring
Instruments in the EU*:
The type-approval certificate for
verification applies only to non-
automatic weighing instruments;
for automatic operation with
or without auxiliary measuring
devices, you must comply
with the regulations of your
country applicable to the place
of installation of your scale.
§ You must calibrate the scale at
the place of installation before
using it as a legal measuring
instrument (see the section
entitled “Calibration/
Adjustment” in this chapter)
$ The temperature range
indicated on the verification ID
label must not be exceeded
during operation

Related product manuals