PR 5210 Transmitter Series
PR 5210/00 Profibus Transmitter
PR 5210/10 Digital Process Transmitter
PR 5210/11 Profibus Transmitter (without Analog Output)
Operating Manual
Operating manual 9499 050 52103 Edition 3 11.11.2004
for PR 5210 Release: 3

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sartorius PR 5210/10 and is the answer not in the manual?

Sartorius PR 5210/10 Specifications

General IconGeneral
Maximum number of load cells4
Housing materialStainless steel
Protection classIP65
Power supply24 V DC
Output signalRS485
Accuracy0.05% of full scale

Summary

Safety Hints, Electrical Protection Class

1.3 Before commissioning

Details essential checks and actions required before the instrument is put into operation.

1.4 Repair and Maintenance

Covers essential safety precautions, installation, and maintenance procedures for safe operation.

PR 5210 Transmitter Series

2.5 Connections

Details all electrical connections for load cells, communication interfaces, digital I/O, and analog output.

OPERATING ELEMENTS

3.1 Status LEDs

Explains the function and meaning of the 5 green LEDs indicating operating and error status.

SETUP AND CONFIGURATION

4.2 Installation Windows tool

Provides steps for installing and launching the PR 5210-WIN Configurator software.

4.3 Load and store setup and configuration

Explains how to upload, download, and archive configuration data for the transmitter.

4.7 ADU

Covers Automatic Data Update parameters, including weighing point calibration.

4.8 Parameter

Details various parameters for analog output, Profibus, communication, and digital I/O settings.

4.9 Calibrate

Guides through the process of performing scale calibration using the software interface.

4.10 Analog Output Adaption

Explains how to adapt the analog output signal for precise current or voltage readings.

SMA PROTOCOL

5.3 Scale Command Set

Lists and explains the commands used to request data and perform operations via the SMA protocol.

PROFIBUS INTERFACE

6.1 Profibus interface protocol

Explains the 8-byte read/write window protocol for Profibus communication.

6.2 Profibus Register

Details the various registers used for reading scale status, data, and configuration via Profibus.

6.3 Profibus Parameter Numbers

Lists parameters for configuration and calibration accessible via Profibus, with their numbers.

TECHNICAL DATA