Parameter 16-bit Register 32-bit Point R/W Unit Range/Scale
1
Reg. Cnv. Register ID Low High
Predicted sliding window kVA
demand
7556 LIN3 14632-14633 0x1614 R kVA 0 Pmax
PF at maximum sliding window
kVA demand
7557 LIN3 14634-14635 0x1615 R 0.001 -1.000 1.000
Total energies
kWh import 7576
7577
14720-14721 0x1700 R kWh 0 10
8
-1
kWh export
4
7578
7579
14722-14723 0x1701 R kWh 0 10
8
-1
Reserved 7580
7581
14724-14725 0x1702
R 0 0
Reserved 7582
7583
14726-14727 0x1703 R 0 0
kvarh import 7584
7585
14728-14729 0x1704 R kvarh 0 10
8
-1
kvarh export
4
7586
7587
14730-14731 0x1705
R kvarh 0 10
8
-1
Reserved 7588
7589
14732-14733 0x1706 R 0 0
Reserved 7590
7591
14734-14735 0x1707 R 0 0
kVAh total 7592
7593
14736-14737 0x1708 R kVAh 0 10
8
-1
Phase energies
kWh import L1 7616
7617
14848-14849
0x1800
R kWh 0 10
8
-1
kWh import L2 7618
7619
14850-14851
0x1801
R kWh 0 10
8
-1
kWh import L3 7620
7621
14852-14853
0x1802
R kWh 0 10
8
-1
kvarh import L1 7622
7623
14854-14855
0x1803
R kvarh 0 10
8
-1
kvarh import L2 7624
7625
14856-14857
0x1804
R kvarh 0 10
8
-1
kvarh import L3 7626
7627
14858-14859
0x1805
R kvarh 0 10
8
-1
kVAh total L1 7628
7629
14860-14861
0x1806
R kVAh 0 10
8
-1
kVAh total L2 7630
7631
14862-14863
0x1807
R kVAh 0 10
8
-1
kVAh total L3 7632
7633
14864-14865
0x1808
R kVAh 0 10
8
-1
Fundamental's (H01) real-time values per phase
Voltage L1/L12
6
8296 LIN3 17024-17025 0x2900 R V 0 Vmax
Voltage L2/L23
6
8297 LIN3 17026-17027 0x2901 R V 0 Vmax
Voltage L3
6
8298 LIN3 17028-17029 0x2902 R V 0 Vmax
Current L1 8299 LIN3 17030-17031 0x2903 R A 0 Imax
Current L2 8300 LIN3 17032-17033 0x2904 R A 0 Imax
Current L3 8301 LIN3 17034-17035 0x2905 R A 0 Imax
kW L1 8302 LIN3 17036-17037 0x2906 R kW -Pmax Pmax
kW L2 8303 LIN3 17038-17039 0x2907 R kW -Pmax Pmax
kW L3 8304 LIN3 17040-17041 0x2908 R kW -Pmax Pmax
kvar L1 8305 LIN3 17042-17043 0x2909 R kvar -Pmax Pmax
kvar L2 8306 LIN3 17044-17045 0x290A R kvar -Pmax Pmax
kvar L3 8307 LIN3 17046-17047 0x290B R kvar -Pmax Pmax
kVA L1 8308 LIN3 17048-17049 0x290C R kVA 0 Pmax
kVA L2 8309 LIN3 17050-17051 0x290D R kVA 0 Pmax
kVA L3 8310 LIN3 17052-17053 0x290E R kVA 0 Pmax
Power factor L1 8311 LIN3 17054-17055 0x290F R 0.001 -1.000 1.000
Power factor L2 8312 LIN3 17056-17055 0x2910 R 0.001 -1.000 1.000
Power factor L3 8313 LIN3 17058-17059 0x2911 R 0.001 -1.000 1.000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Satec PM130EH SERIES and is the answer not in the manual?

Satec PM130EH SERIES Specifications

General IconGeneral
DisplayLCD
Frequency50/60 Hz
CommunicationRS-485, Modbus RTU
Digital Outputs2 relay outputs
Data LoggingYes
Measurement TypePower, Energy, Harmonics
Current Input1A or 5A
MountingPanel Mount
Power Supply85-265V AC/DC
Digital Inputs2
Analog OutputsUp to 4
Operating Temperature-20 to 70°C
Dimensions96 x 96 mm
Weight0.5kg

Related product manuals