SATEL INTEGRA 31
DLOADX program settings
You can configure the modem communication settings in the “Configuration” window,
“Modem” tab.
Description of parameters
Telephone numbers
Panel’s tel. no telephone number of the control panel.
PC phone number telephone number of the modem connected to computer with DLOADX
program installed.
Control panel settings
Parameters and options related to modem communication are described in section
Telephone options” (p. 71). For description of additional parameters related to the
INTEGRA 128-WRL, see section GSM phone(p. 79).
DLOADX program settings
You can define three sets of parameters for the modem connected to computer:
analog modem for communication with the built-in modem of the control panel,
analog modem for communication with the external modem of the control panel,
ISDN or GSM modem for communication with the ISDN or GSM modem of the control
panel.
After clicking on the button you can configure the selected set of parameters (see:
Configuring the modem connected to computer”).
Dialing the method of dialing numbers by the modem connected to computer (tone or
pulse).
Dial tones control if option is enabled, the modem connected to computer will detect the
dial tone or busy signal before dialing the number.
Speaker operating mode of the modem speaker. The speaker can be always OFF, or ON
until connection with the control panel is established (auto), or always ON.
Volumevolume of modem speaker.
Answering how the DLOADX program reacts when the control panel is connecting to the
program. Communication can be established automatically after a preset number of rings,
or the program will only indicate an attempt to establish communication by the control
panel (communication will only be established after clicking on the “Answer” button).
Double call you can define duration of the pause between the first and the second call, if
the control panel is set to go off-hook after the second call.
Configuring the modem connected to computer
You can edit the parameters after clicking on the “Change” button.
Port RS-232computer COM port to which the modem is connected.
Modem list of modems, the parameters of which are defined. The list of modems and their
settings will be written to disk in the “modem.ini” file.
Baud Rate transmission rate of the serial port. It is recommended that the highest rate
acceptable by the modem be set (only some modems may require the 300 bps setting in
order to enforce operation with exactly this speed).
Reset command the command to reset the modem. Typically, it is the ATZ command
(reset with restoration of the user's zero profile). Some modems may require using the
AT&F command (reset with restoration of the factory default settings).