14 CL608e/612e
3. Configuration Operation Manual
3.1.1 RS232 Transmit/Receive Setting
Data Bit Selection (DSW1-1)
This switch sets the printer to receive either 7 or 8 bit data bits for
each byte transmitted.
Parity Selection (DSW1-2, DSW1-3)
These switches select the type of parity used for error detection.
Stop Bit Selection (DSW1-4)
Selects the number of stop bits to end each byte.
Baud Rate Selection (DSW1-5, DSW1-6)
Selects the data rate(bps) for the RS232 port.
* Factory Default
DSW1-1 SETTING
*
OFF
8 Data Bits
ON 7 Data Bits
12 345678
ON
OFF
DSW1
1 2 3 4 5 6 7 8
ON
OFF
DSW1
DSW1-2 DSW1-3
SETTING
*OFF *OFF No Parity
OFF ON Even
ON OFF Odd
ON ON Not Used
DSW1-4 SETTING
*OFF
1 Stop Bit
ON 2 Stop Bits
12 345678
ON
OFF
DSW1
DSW1-5 DSW1-6 SETTING
*
OFF
*
OFF
9600
OFF ON 19200
ON OFF 38400
ON ON 57600
12 345678
ON
OFF
DSW1