Section 3. Configuration
Page 3-2 PN 9001105 Rev. A SATO M-84PRO
Stop Bit Selection (DSW1-4). Selects the number of stop bits to end each byte transmission.
Baud Rate Selection (DSW1-5, DSW1-6). Selects the data rate (bps) for the RS232 port.
Protocol Selection (DSW1-7, DSW1-8). Selects the flow control and status reporting
protocols. See Section 6: Interface Specifications for more information. (* Will select the
Status 2 protocol if DSW2-8 is ON).
PRINTER SET UP
Print Mode Selection (DSW2-1). Selects between direct thermal printing on thermally
sensitive paper and thermal transfer printing using a ribbon.
DSW1-4 SETTING
Off 1 Stop Bit
On 2 Stop Bits
DSW1
ON
OFF
12345678
DSW1-5 DSW1-6 SETTING
Off Off 9600
Off On 19200
On Off 38400
On On 57600
DSW1
ON
OFF
12345678
DSW1-7 DSW1-8 SETTING
Off Off Rdy/Bsy
Off On Xon/Xoff
On Off Bi-Com 3
On On Bi-Com 4
DSW1
ON
OFF
12345678
DSW2-1 SETTING
Off Therm Xfr
On Direct Therm
DSW2
ON
OFF
12345678