39
6.8.2 Printer Error Information
Errors happening at the printer need to be disclosed because the printer supports MIB host and printerMIB. When the printer received a request of error information acquisition
from SNMP manager, the printer return the response data by replacing the printer error number to the error code defined by MIB.
6.8.2.1 Error and warning MIB correspondence table
Printer MIB
Host Resources MIB
Description
prtAlertSeverity
Level
prtAlertTraining
Level
prtAlertGroup
prtAlertCode
hrPrinterDetected
ErrorState
hrDeviceStatus
hrPrinterStatus
Online
-
-
-
-
-
running(2) / *1
warning(3)
idle(3) / *2
printing(4)
Offline
critical(3)
untrained(3)
generalPrinter(5)
subunitOffline(22)
bit #6 (offline)
down(5)
other(1)
Print pause
-
-
-
-
-
running(2) / *3
warning(3)/down(5)
other(1)
Flash ROM error
critical(3)
fieldService(5)
other(1)
other(1)
-
down(5)
other(1)
EEPROM error
critical(3)
fieldService(5)
other(1)
other(1)
-
down(5)
other(1)
Head error
critical(3)
fieldService(5)
marker(10)
other(1)
-
down(5)
other(1)
Head open
critical(3)
untrained(3)
marker(10)
subunitOpened(18)
bit #4 (doorOpen)
down(5)
other(1)
Paper end error
critical(3)
untrained(3)
input(8)
inputMediaSupplyEmpty(808)
bit #1 (noPaper)
down(5)
other(1)
Sensor error
critical(3)
trained(4)
mediaPath(13)
jam(8)
bit #5 (jammed)
down(5)
other(1)
Cutter error
critical(3)
trained(4)
finDevice(30)
separationCutterJam(31108)
bit #5 (jammed)
down(5)
other(1)
Ribbon end
critical(3)
untrained(3)
markerSupplies(11)
markerPrintRibbonEmpty(1103)
bit #3 (noToner)
down(5)
other(1)
Flaming error
critical(3)
other(1)
channel(14)
other(1)
-
down(5)
other(1)
Low battery error
critical(3)
untrained(3)
other(1)
subunitAlmostEmpty(12)
-
down(5)
other(1)
USB error
critical(3)
other(1)
other(1)
other(1)
-
down(5)
other(1)
WLAN Module error
critical(3)
fieldService(5)
channel(14)
subunitUnrecoverableFailure(30)
-
down(5)
other(1)
Bluetooth module error
critical(3)
fieldService(5)
channel(14)
subunitUnrecoverableFailure(30)
-
down(5)
other(1)
Command error
critical(3)
other(1)
nterpreter(15)
other(1)
-
down(5)
other(1)
Print head overheat
critical(3)
other(1)
marker(10)
subnitOverTemperature(36)
-
down(5)
other(1)
*1 warning (3) is set at warning during online state. Other than that, running (2) is set.
*2 printing (4) is set during printing. Other than that, idle (3) is set.
*3 running (2) is set at online, warning (3) is set at warning during online state, and down (5) is set at offline.
6.8.2.2 Supplemental explanation
1) The last error has the priority when multiple error has happened.
2) If errors and warnings happened at the same time, Host Resources MIB and Printer MIB are notified as error.
3) If a multiple warning happened, printer MIB is notified multiply (prtAlert).