Copyright © 2018 Savant Systems, LLCEntry Service with 2N Door Stations Deployment Guide
009-1540-00 | 181026
13 of 29
5.3. Services
In a web browser log in to the Door Station to be configured.
1. Select Services
1
2. Select Phone > Calls.
3. Set Incoming Calls to Automatic for both SIP1 and SIP2.
3
5
4
4. Set Call Time Limit.
This is a max duration of the call before the intercom terminates
the call.
HELPFUL INFO: Setting the “Call Time Limit” to zero will make the
call have an unlimited time.
5. Click Save
6. Select Phone > Audio
7. Enable PCMA, PCMU and G.722.
7
8
8. Set Priority:
PCMA - 1 Highest
PCMU - 2
G.722 - 3
9. Click Save.