© Scania CV 2009 47
Renewing the battery
Removing
1. Disconnect the negative cable (-) from the battery (cable connected to
earth).
2. Disconnect the positive cable (+) from the battery (cable connected to
starter motor).
Fitting
1. Connect the positive cable (+) to the battery (cable connected to starter
motor).
2. Connect the negative cable (-) to the battery (cable connected to earth).
17. Every 1,200 hours:
Checking coolant level monitor
(Optional equipment)
1. Start the engine.
2. Lower the coolant level in the expansion tank.
3. Automatic stop in the event of a fault: The engine stops, the indicator
lamp comes on and the buzzer (if fitted) sounds if there is no fault in the
level monitor. If the function is connected via the coordinator, the
emergency stop fault code will be generated and can be read off on the
diagnostics lamp.
4. No automatic stop in the event of a fault: The indicator lamp comes on
and the buzzer (if fitted) sounds if there is no fault in the level monitor.
5. Top up coolant to the correct level, see page 36.
Do not connect the terminals
incorrectly.
This can cause serious damage
to the electrical system.
If the terminals are shorted,
sparking will occur.
Dispose of used batteries
through an authorised waste
disposal contractor.
2-pin level monitor installed in the
expansion tank for radiators
supplied by Scania
Use a container to avoid spills
when draining the coolant.
Dispose of used coolant through
an authorised waste disposal
contractor.