Scania DC12 - Renewing (or Cleaning) the Closed Crankcase Ventilation Valve

Scania DC12
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56 © Scania CV 2009
22. Every 2,400 hours:
Renewing (or cleaning) the closed
crankcase ventilation valve
Alternative 1:
Renew the valve at the specified interval.
Alternative 2:
- Dismantle the valve after the specified interval.
- Clean the valve by placing it in a bath of diesel fuel oil overnight. Then
rinse it several times in diesel oil and allow it to drip dry.
- Refit the valve.
- The valve may be reused (cleaned), but not more than twice after the
first 2,400 hours of use. Take care to mark the valve after cleaning it.