Schaerer Coffee Art C - Generic 24mo Preventative Maintenance SOP
Locating the Air Valve:
Using the short Schaerer tool:
• Unscrew the four screws on the top panel. Remove the top panel.
• Unscrew the two screws on the back panel. Remove the back panel.
Locate the air valve as circled in red in the image below:
Adjusting the Air Valve:
Using a fl at head:
• Tighten / close the valve by turning screw clockwise from top until stop
NOTE: Don’t tighten it too hard to avoid damaging the parts
• Loosen / open by 1 turn (360 degrees) by turning counter-clockwise from top
Once the air valve is adjusted, dispense two of a hot drink and iced drink and
observe any spitting from the spout in the beginning and end of dispensing.
NOTE: If spitting is still observed, slightly close the screw (turning clockwise)
until there is no spitting and re-run drinks. If there is residual coff ee remaining
in the brewing lines, slightly open the screw until dispensing runs smoothly.
Once complete, use the short Schaerer tool to screw the panels back on.
7G. Air Valve Adjustment