Operating manual VISATRON® Oil Mist Detector VN2020 / VN2020 EX
Part number 183001 Version 3.0
113
OPERATION AND USE
VN2020 measuring head: “Alarm” status indicator at 100% OMC
1: Confirmation button
3: System status
2: Display; Relative Oil Mist Concentration
8.9 Confirming an oil mist alarm
DANGER
Risk of death
There is a risk of serious injury, including death, due to explosion in the crankcase as a
result of incorrect installation.
In the event of an oil mist alarm, do not approach the engine again until the
alarm threshold has dropped to at least < 50% relative oil mist concentration.
The manufacturer recommends that only approach the engine again when the
alarm threshold has dropped to 0% relative oil mist concentration.
If a Remote Indicator II is used for remote monitoring, it must be used to
continuously check the current oil mist concentration.
Familiarise yourself with the basic safety instructions before starting to operate
the device.
Section 2.4 Basic safety instructions
If the oil mist detector is operated in explosion-proof areas, the relevant safety
instructions must be observed.
Section 2.4.1 Safety instructions for potentially
explosive atmospheres
CAUTION
Confirming an oil mist alarm
Only confirm the oil mist alarm using the confirmation button if you have
previously made sure that there are no more high oil mist concentrations in the
crankcase, or as soon as the concentration is below the alarm limit displayed
(<70%).
1. The oil mist alarm message must be confirmed by pressing the button [] on the
VISATRON
®
VN2020 measuring head.
LED
flashing
LEDs
come on

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schaller Automation Visatron VN2020 and is the answer not in the manual?

Schaller Automation Visatron VN2020 Specifications

General IconGeneral
BrandSchaller Automation
ModelVisatron VN2020
CategorySecurity Sensors
LanguageEnglish

Related product manuals