Operating manual VISATRON® Oil Mist Detector VN2020 / VN2020 EX
Part number 183001 Version 3.0
67
ASSEMBLY AND INSTALLATION
1: Filling pump
3: Filling adapter
2: Straight screw-in socket L10
NOTE
Installing the filling pump with filling pipe on the pipe siphon
Start by filling the filling pump (1) with 70 ml of lubrication oil approved by the
engine manufacturer/engine's own lubrication oil.
Insert the filling adapter (3) into the straight screw-in socket L10 (2) as far as it
will go.
Fill the pipe siphon via the straight screw-in socket L10 (2) with 70 ml of
lubrication oil (lubrication oil approved by the engine manufacturer/engine's
own lubrication oil).
WARNING
The screw-in socket (2) has to be completely closed by the filling adapter (3).
Excess oil can flow into the crankcase.