5 – FUNCTIONING AND USE COD.30S12/24.A.2018
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
34
After 3-4 minuts switch off the Pump 1 by
turning Pump 1 selector counterclockwise.
7. Switch off the bypass by turnuning
counterclockwise the selector under the
electric box. The green Led will switch off.
8. Turn clockwise the Pump1 and Aut. Washing
selectors and close the depressurization
valve (lever in vertical position).
9. Press the START button. The system stars
to pressurize and the fresh water production
begins.
Verify that no leaks occur. After about 3
minuts, push STOP button. The system
activates washing procedure automatically
amd switchs off after about 40-50 seconds.
The system is now correctly purged and it is
ready to operate normally.
5.4 Normal operating procedure
Please, be sure to perform all the following checks before proceeding normal operating procedure:
1. Be sure the reset valve is closed (lever orthogonal to the body valve) and the positioner completely
unscrewed.
2. Be sure the depressurization valve is closed.