www.scheppach.com
28
|
GB
Rated voltage U
n
2 x 230 V
~
Rated current I
n
7 A (230 V
~
)
Rated current I
n
2 x 2.1 A (USB)
Frequency F
n
50 Hz
Performance class G1
Active power factor φ 1
Quality class A
Drive motor type 4-stroke 1 cylinder
air-cooled
Displacement 79 cm
3
Max. power (engine) 2.2 kW / 3 HP
Fuel Super E10 petrol
Tank contents 4.1 l
Engine oil type 15W40
Oil volume (approx.) 350 ml
Consumption at full load 1.27 l/h
Weight 17.5 kg
Max. temperature. 40
°
C
Max. altitude (above mean
sea level)
1000 m
Spark plug A7RTC
Technical changes reserved!
Operating mode S1 (continuous operation)
The machine may be operated continuously with the
specied power.
Operating mode S2 (short-term operation)
The machine may only be operated at maximum power
for a brief time.
Information about the noise level measured in accord-
ance with applicable standards (EN ISO 3744:1995,
ISO 8528-10:1998):
Sound pressure L
pA
71.6 dB
Sound pressure L
wA
91.6 dB
Measurement uncertainty K
pA
1.13 dB
Wear hearing protection.
Excessive noise can result in a loss of hearing.
7. Unpacking
• Open the packaging and carefully remove the de-
vice.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Open the tank plug carefully and slowly. Wait for the
pressure to equalise and only then remove the tank
cover completely.
• Use a suitable funnel or ller pipe for refuelling so
that no fuel can spill onto the combustion engine and
housing or lawn.
Do not overll the fuel tank!
• To leave room for the fuel to expand, never ll the
fuel tank beyond the lower edge of the lling nozzle.
Observe additional information in the combustion
engine user manual.
• If petrol has overowed, do not start the combustion
engine until the petrol-contaminated area has been
cleaned. Avoid starting the engine until the fuel va-
pours have evaporated (wipe dry).
• Always wipe up spilled fuel immediately.
• If petrol has got on clothing, it must be changed.
• The tank cover must be properly screwed on and
tightened after each refuelling operation. The device
must not be put into operation without the original
tank cover screwed on.
• For safety reasons, check fuel line, fuel tank, tank
plug and connections regularly for damage, ageing
(brittleness), tight t and leaks and replace if nec-
essary.
• Only empty the tank outdoors.
• Never use beverage bottles or similar to dispose of
or store operating materials, such as fuel. People,
especially children, could be tempted to drink from it.
• Never store the device with petrol in the tank inside
a building. Any fuel vapours produced can come into
contact with naked ames or sparks and ignite.
• Do not place the device and fuel tank near heaters,
radiant heaters, welding machines or other sources
of heat.
Risk of explosion!
If a defect is detected on the tank, the tank cover or
on fuel-carrying parts (fuel lines) during operation, the
combustion engine must be switched o immediately.
Then consult a specialist dealer.
6. Technical data
Power generator Digital inverter
Protection category IP23M
Continuous output P
n
(COP)
(230 V) (S1)
1.6 kW
Max. power P
max
(230 V)
(S2 5min)
2.0 kW