Assembly
03.00 | AGE-XY | Assembly and operating manual | en | 389007
15
4.3.1 MMS 22 magnetic switch
ca.
brown
black
blue
load
closer
CAUTION
Risk of damage to the sensor during assembly!
Observe the maximal tightening torque.
NOTE
Ferromagnetic material changes the switching positions of the
sensor. For example: Adapter plate made of ordinary steel.
At ferromagnetic adapter plates:
First mount the product on the adapter plate.
Then set the position of the magnetic switch.
NOTE
Do not use the sensor as a safety component.
Do not pull on the cable of the sensor.
Secure the cable and connection plug so that they are not
taught and cannot move during operation.
Do not exceed the permitted bending radius of the cable.
Do not allow the sensor to come into contact with hard objects
and chemicals (e.g., nitric acid, chromic acid and sulfuric acid).