DC.R340TT.MAN.001—01—User Manual SDT340TANKTEST EN
7/44
In particular, this procedure is not applicable to tanks that have been converted to a double shell design
using:
- A flexible inner lining.
- Reinforced plastic lining.
For these installations, please follow the instructions of the contractor or applicator.
Failure to comply with these normative constraints exposes the operator to risks of
deformation of the tank leading to a destructive test having no regulatory value. SDT
International cannot be held responsible, in case of disregard of the test procedures
6. Unpacking
The items that follow are included in your purchase of the SDT340 TankTest kit. Unpack and inspect
them.
• SDT340
• Wired headset
• Spiral Cable, 2 male 7-pole LEMO
connectors
• TankTest sensors (TTR2, TTB2)
mounted on the Camlock
• Flexible Sensor
• USB communication cable
• USB key containing user manuals
• TankTest reporter software
• Battery pack
• Battery charger, power cord, EU, US
and UK plugs
• Battery docking station
• Shoulder strap
• Multi-function screwdriver
7. Battery
Only use the docking station and the power supply provided by SDT.
Do not store an uncharged battery for more than a few weeks.
Perform preferably a complete charge cycle.
Charge the battery at least every 3 months, even not used.
The SDT340 operates on a rechargeable Nickel Metal Hydride (NiMH) battery. After unpacking the unit,
please fully charge the battery pack before its first use. To charge the battery pack:
• Plug the power supply (*) to the main and connect it ❶ to the docking station. Then the LED
is blinking blue.
• Loosen the quick fastener using the screwdriver and remove the battery pack from the unit.
• Place the battery pack in the docking station ❸. The LED should stay on blue a few seconds
and then flash green. Otherwise, perform a force charging by inserting a needle in the reset
location ❷.
• When the LED is continuously lit green, the battery is fully charged.