38JDL V1.0 8 2022
1. Press Service Mode Buon
2. Press 5 for Opons Menu
3. Press 8 for Set Point
4. Press 8 to edit the temperature Set Point
5. Connue pressing 8 unl the desired temperature is shown on the display (0-250)
6. Press # to save changes
7. Press * to exit to previous menu
SENSITIVITY ADJUST
Allows you to adjust the Drop Sensor Sensivity for each Beverage Lane (140-146)
1. Press Service Mode Buon
2. Press 5 for Opons Menu
3. Press 9 for Sensivity Adjust
4. Press 3 for Selecon
5. Use number to enter Selecon number (140-146)
6. Press 1 to toggle through Low, Mid or High
7. Press # to save changes
8. Press * to exit to previous menu
6. ADVANCED*
This menu requires a password. The factory default password is 2314. The following sub-menus are
included in the Advanced Features menu:
• Discount • Shutdown
• Exact Change • Energy Savings
• Uncondional Acceptance • Paired Motors
• Max Change • Degrees
• Currency
DISCOUNT ALL ITEMS
This menu uses various sub-menu sengs to allow a dierent price for selecons at dierent mes or on
dierent days. Only one discounted price can be set for each item, whether by All Items, Row or Selecon
but various me intervals can be applied.
1. Press Service Mode Buon
2. Press 6 for Advanced Menu
3. Use number keys to enter Password (2314)
4. Press 1 for Discount
5. Press 7 for All Items
6. Use keypad to enter discount price for All Items
7. Press # to save changes
8. Press * to exit to previous menu
9. Press 1 for Interval1 (up to 4 Intervals may be chosen)
10. Press 1 for All Items