The user can change settings and observe real-time measurements in the following parameters.
The table in 4.1 Parameter Overview is intended for easy reference.
For more detail, please refer to 4.2 Description of Parameters.
Parameter
Group
Parameter text Description Default Min
value
Max
value
Step
size
Unit Type
Main functions
Main switch
ON/OFF regulation of power sup-
ply to controller
0 0 1 1
0 = OFF
1 = ON
Setting
Reset power con-
sumption
Resets cumulative power con-
sumption of the entire system
to zero
0 0 1 1
0 = OFF
1 = ON
Setting
Total power con-
sumption
Real-time power consumption of
the entire system
0 65535 10 W
Measure-
ment
Total power con-
sumption since
start
Cumulative power consumption
of the entire system since the
most recent startup
0 65535 10 Wh
Measure-
ment
Total power con-
sumption last
period
Cumulative power consumption
of the entire system in the pre-
vious period
0 65535 10 Wh
Measure-
ment
Main functions Compressor 1
Reset power con-
sumption
Resets cumulative power con-
sumption of Compressor 1 to
zero
0 0 1 1
0 = OFF
1 = ON
Setting
Total power con-
sumption
Cumulative power consumption
of Compressor 1
0 65535 10 W
Measure-
ment
Total power con-
sumption since
start
Cumulative power consumption
of Compressor 1 since the most
recent startup
0 65535 10 Wh
Measure-
ment
Total power con-
sumption last
period
Cumulative power consumption
of Compressor 1 in the previous
period
0 65535 10 Wh
Measure-
ment
4.1
Parameter Overview
4.