3
Operating
Instructions
The Secop BD compressors with 101N08xx Series 12-24V DC are designed for use in:
Comfort cooling in parking anti-idle applications
Spot and comfort cooling in buses, golf carts, smaller boats, forklifts, campers etc
Cooling of switchboards and batteries in radio stations for cellular phones
Mobile refrigeration applications
Air cargo cooling
Mobile cooling boxes of volume up to 1000L
Mobile refrigeration applications
For R134a compressor variants:
One application module can control either single or twin compressor configurations.
The cooling capacity of the single compressor configuration is approx. 900 Watt @ Pe/Pc
~+15/+55°C
The cooling capacity of the twin compressor configuration is approx. 1800 Watt @ Pe/Pc
~+15/+55°C
The system is able to operate in ambient temperatures up to +55 ºC.
The operating conditions are High Back Pressure (HBP).
For R404A/R507 compressor variants:
The cooling capacity of the compressor is approx. 380 Watt @ Pe/Pc ~-5/+55°C
The system is able to operate in ambient temperatures up to +55 ºC.
The operating conditions are Low Back Pressure (LBP).
The main functions of the controllers are:
Operation using either 12 V DC or 24 V DC
Simultaneous and independent control of two compressors in twin configuration
ECO function to optimize compressor speed for minimum power consumption
Detailed error log
Event log
Motor / Compressor speed control
Thermostat control (ON / OFF or electronic via NTC temperature sensor)
Condenser fan control
Evaporator fan control
Communication interface
Monitoring function
Battery protection functions
Main Switch
Log of specific parameters
Optimization of specific parameters via PC software before commencing mass production
The controller can be accessed using either
The Secop software tool Tool4Cool
®
LabEdition, or
A custom interface. Please contact Secop for further information regarding custom interfaces
1.
INTRODUCTION
1.1
Applications
1.2
Capability
1.3
Functions
1.4
Programming
Interface

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SECOP 101N08 Series and is the answer not in the manual?

SECOP 101N08 Series Specifications

General IconGeneral
BrandSECOP
Model101N08 Series
CategoryController
LanguageEnglish

Related product manuals