4.3.1 Error log
The error log records the following data for each error arising:
Time of occurrence related to compressor power up, with 1 sec as sample time
The sequence of occurrence
Number of occurrence (when no value is related to the parameter)
Error name
Sub Error name
The value of the parameter which caused the failure (if connected to a parameter)
Event list reference (changes which caused the failure if a parameter change caused the failure)
The error log can be cleared using the clear function.
4.3.2 Event log
The event log records the following parameter and event data to assist in service situations:
Parameter changes (Parameters defined in the parameter)
Power up
Start/Stop signal from application module
The following information is recorded for each event:
Time of occurrence related to compressor power up, with 1 sec as sample time
The sequence of occurrence (Event list reference)
Parameter/Event description
The value of the parameter
Number of occurrence (when no value is related to the parameter)
4.3
Error and Event Logs

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SECOP 101N08 Series and is the answer not in the manual?

SECOP 101N08 Series Specifications

General IconGeneral
BrandSECOP
Model101N08 Series
CategoryController
LanguageEnglish

Related product manuals