37
Operating
Instructions
Battery Protection
Max limit
Cut-in level
Cut-out level
Critical stop
Restart delayCut-out delay
ON
ON
ON
OFF
OFF
OFF
(Voltage failure)
Alarm state
Comp. state
message
Cond. & evap. fan
For initial startup after power ON, extra protection has been provided by allowing cut in only
when the voltage exceeds cut out + 1 V DC :
Battery Protection
first start after power supplied
Max limit
Cut-in level
Cut-out level
Cut-out + 1 VDC
Critical stop
Restart delay
Cut-out delay
Alarm state
Comp. state
message
Cond. & evap. fan
(Voltage failure)
ON
ON
ON
OFF
OFF
OFF
Settings:
Name Default Max value Min value Step Unit
Battery cut-out level
12 V DC power supply
10.4 17.0 9.6 0.1 V DC
Battery cut-out level
24 V DC power supply
21.3 27.0 19.0 0.1 V DC
Battery cut-in
difference
power supply
1.3 10.0 0.5 0.1 V DC
Cut-out delay 3 60 0 1 sec