11-3 Repair and maintenance for mobile potentiometer (left and right).
11-4 Repair and maintenance for the mobile potentiometer (up and down).
Unscrew 3PCS of M4*8 with 3mm hexagonal key
Disassemble
M4 screw with
7mm sleeve
Test the Potentiometer with
multimeter, and the normal
value should be between
0~5K.
Regularly clean the gear,
and add lubricating oil,
so as to keep the gear
running smoothly.
Test the Potentiometer with
multimeter, and the normal
value should be between 0~5K.
Regularly clean the gear and
add lubricating oil, so as to
keep the gear running
smoothly.
11. REPAIR & MAINTENANCE FOR CONTROLLER PART