ARC AIR / LIFT
*** the maximum current value depends on the power source (PSR503=500A, PSR352=350A).
1.3.8
WF 111 default settings
The default settings for the main menu, quick menu and set-up of the related parameters are listed below for each procedure. The
synergic parameters are highlighted in bold.
MIG SYNERGIC (procedure set by default)
* the Min, Max limit values represent the maximum values permitted and vary according to the synergic program selected.
** parameters displayed in the quick menu if enabled by the related function.
*** the maximum current value in synergy depends on the power source unit with a higher tolerance range (roughly: PSM408=400A,
PSM508=500A, PSM708=700A); the maximum value of 550A for 2 sec. is valid for all welding units and beyond this valus the over-
current alarm turns on.
**** default values for PSM408/508 o PSM708
# synergic parameter correction.
MAIN MENU
Current set
Voltage reading
SET-UP MENU CH1 RC07
QUICK MENU
Current set
Current reading
Voltage reading
SET-UP MENU
2-Current set
40-Current reading
41-Voltage reading
48-Buzzer tone
49-LCD contrast
45-CH1: min current set
RC07
45-CH1: max current set
RC07
SYMBOL
#
MIN
Off (0)
1,0 *
6 *
0,8 *
10,0*
-9,9 *
1
Off (0)
0,01
10
0,0
0,0
20
20
0,1
0,1
Off (0)
0,0
-
-
-
Off (0)
0
1,0
min+1
-9,9
min+0,1
MAX
31
22,0 *
Imax ***
25,5 *
50,0 *
+9,9 *
3
12
2,00
100
10,0
10,0
200
200
25,0
25,0
100
2,00
-
-
-
10
50
max-1
22,0
max-0,1
+9,9
DEF
5
1,5
-
-
-
0,0
-
2 o 1****
0,02
50
0,1
2,0
120
80
1,0
1,0
25 o 15****
0,8
-
-
-
5
25
1,0
22,0
-9,9
+9,9
UM
-
mt/min
A
mm
V
%V
-
-
s
%
s
s
%
%
s
s
%
s
A
V
lt/min
-
-
mt/min
mt/min
V
V
SYMBOL MIN
6
-
-
Off (0)
0
6
min+1
MAX
Imax ***
-
-
10
50
max-1
Imax ***
DEF
100
-
-
5
25
6
Imax ***
UM
A
A
V
-
-
A
A
MAIN MENU
Wire speed
Synergy voltage
Offset voltage
SET-UP MENU CH1 RC07
SET-UP MENU CH2 RC07
QUICK MENU
Program number
Wire speed
Current
Thickness
Synergy voltage
Offset voltage
Inductance
Initial increase **
Crater Filler **
Spot welding time **
Pause time **
SET-UP MENU
2-Program number
3-Wire speed
4-Current
5-Thickness
6-Synergy voltage
6-Offset voltage
7-Inductance
8-Burn back impulse
9-Burn back
10-Softstart
11-Pre-gas time
12-Post-gas time
13-Initial increase
14-Crater Filler
15-Spot welding time
16-Pause time
17-Hot start percentage
18-Hot start time
40-Current reading
41-Voltage reading
42-Gas flow reading
48-Buzzer tone
49-LCD contrast
45-CH1: min wire speed
RC07
45-CH1: max wire speed
RC07
46-CH2: min voltage off-
set RC07
46-CH2: max voltage off-
set RC07
29