6
Appendix
Description of the access points
Manual – ECDriveS
®
42
Process
data word
[PI]
Data
type
Designation Bytewise
notation
[byte.bit]
Wordwise
notation
[word.bit]
Description
12
Int
ReleaseCounterUp-
streamZone
24.0
24.7
12.0
12.15
Release of the counter of the upstream zone. Reflects
the value in ReleaseControlUpstream
25.0
25.7
13
Int
ReleaseCounterDown-
streamZone
26.0
26.7
13.0
13.15
Release of the counter of the downstream zone. Re-
flects the value in ReleaseControlUpstream
27.0
27.7
14
Dword ModuleDischargeTracking
28.0
28.7
14.0
14.15
Read ZPA tracking data of the last zone. Tracking code
of the material being transported that is currently being
transfered to an adjacent section of the system (not part
of the ECDriveS
®
conveyor line)
29.0
29.7
15 30.0
30.7
15.0
15.15
31.0
31.7
16 ModuleDischargeTrackingIn-
verse
32.0
32.7
16.0
16.15
Read ZPA tracking data of the last zone. Tracking code
of the material being transported that is currently being
transfered to an adjacent section of the system (not part
of the ECDriveS
®
conveyor line) with inverted direction
of flow (current direction of flow ≠ configured direction of
flow)
33.0
33.7
17 34.0
34.7
17.0
17.15
35.0
35.7
18
Struct AllSensors
36.0
36.6
18.0
18.6
Res.
Bool 36.7 18.7 Heartbeat
Bool 37.0 18.8 LeftPin2: Status of the left sensor port (Pin2)
Bool 37.1 18.9 Res.
Bool 37.2 18.10 RightPin2: Status of the right sensor port (Pin2)
Bool 37.3 18.11 Res.
Bool 37.4 18.12 LeftPin4: Status of the left zone sensor port (Pin4)
Bool 37.5 18.13 Res.
Bool 37.6 18.14 RightPin4: Status of the right zone sensor port (Pin4)
Bool 37.7 18.15 Res.
19 Word Res. 38 19
39
20 Struct
Bool
Convey_stop_status 40.0 20.0
Res.
Bool 40.1 20.1 Res.
Bool 40.2 20.2
StopActiveCommandPLC: Fieldbus controller was
given the status Stop by the PLC
40.3
40.7
20.3
20.7
Res.
41.0
41.4
20.8
20.12
Res.
Bool 41.5 20.13
StopActiveOtherModule: A fieldbus controller in the
Stop group currently has the status Stop. (If nec., de-
clare as Res.)
Bool 41.6 20.14
StopActiveLostConn: Communication connection lost.
Fieldbus controller was given the status Stop
Bool 41.7 20.15
StopActiveLostPLC: Missing connection to the PLC.
Fieldbus controller was given the status Stop
Reserved up to byte 63.
25938274/EN – 01/2019