2
Interface box
Maintenance switch
Addendum to the Operating Instructions – MOVIPRO
®
– Accessories
10
The maintenance switch is used to interrupt the AC400V voltage supply to the inter-
face box. The maintenance switch can be secured with 3 locks. If the maintenance
switch is in position0, the MOVIPRO
®
is disconnected from the AC400V voltage sup-
ply.
Depending on the device type, the interface boxes are equipped with different main-
tenance switches:
D.. disconnection switch
M.. line and device protection
2.6.1 D.. disconnection switch
The following disconnection switches are possible, depending on the device's power
rating:
Power Short designation Description
Up to 7.5kW D02 Disconnection switch up to 16A
Up to 15kW D03 Disconnection switch up to 32A
Up to 22kW D04 Disconnection switch up to 42A
2.6.2 M.. line and device protection
The following line and device protection is possible depending on the power:
Power Short designation Description
Up to 2.2kW M13 Line and device protection up to 5A
Up to 4kW M14 Line and device protection up to 9A
Up to 7.5kW M16 Line and device protection up to 15A
23106913/EN – 02/2018