2
Interface box
Electrical installation
Addendum to the Operating Instructions – MOVIPRO
®
– Accessories
13
2.8.3 Connection to MOVIPRO
®
Function
• AC400V device supply output
• DC24V output and input
• With signal contact for maintenance switch
Connection type
Han-Modular
®
10 B, female
Connection image
[a] Han
®
-C module, female
No. Name Function
1 L1 Supply system phase 1
2 L2 Supply system phase 2
3 L3 Supply system phase 3
[b] Han
®
-EE module, female
Coding of the device power, see chapter "Coding"(→214)
[c] Han
®
-EE module, female
No. Name Function
1 +24V_C DC24V input – backup voltage
2 SC Signal contact for maintenance switch
3 VO24 DC 24 V output
4 n.c. Not connected
5 0V24_C 0V24 reference potential – backup voltage
6 n.c. Not connected
7 GND Reference potential
8 n.c. Not connected
Hinged frame
No. Name Function
– PE PE connection