AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 4
S
W
10
1 Measurement of
communication time
(image)
1: Yes 0: No
Ye s 1
2 Sender’s telephone
number registration
1: Inhibit 0: Allow
Allow 0
3 Inhibited to use 0
4 0
5 0
6 ECM byte/frame 1: 64 [bytes/frame] 0: 256 [bytes/frame] 256 [bytes/frame] 0
7 Inhibited to use 0
8 0
S
W
11
1 Inhibited to use 0
2 0
3 0
4 1
5 1
6 0
7 1
8 0
S
W
12
1 Call time setup in
automatic transmission
(T0 timer setup)
Binary input
45sec
0 When a value outside
the set range is set,
the initial value is set.
2 Bit No.
Set range
1234
30 to 75sec
5sec unit
N x 5 + 30sec
0
3 1
4
1
5 Inhibited to use 0
6 CI detection Bit No. 6 7
4 sine wave
0
When a value outside
the set range is set,
the initial value is set.
4 sine wave 0 0
7 3 sine wave 1 0
0
2 sine wave 0 1
8 Inhibited to use 0
S
W
13
1 Inhibited to use 0
2 0
3 Ringing volume Bit No. 3 4
Medium
1
Refer to User program
“RINGER VOLUME”.
Silent 0 0
Small 0 1
4Medium10
0
Large 1 1
5 Speaker volume in DTMF
send
Bit No. 5 6
Medium
1Not used 0 0
Small 0 1
6Medium10
0
Large 1 1
7 Inhibited to use 1
8 1
S
W
14
1 Inhibited to use 0
2 1
3 0
4 1
5 0
6 0
7 0
8 0
SW
NO.
Data
No.
Item Switch selection and contents of functions Initial value Remark

Table of Contents

Other manuals for Sharp AL-2020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AL-2020 and is the answer not in the manual?

Sharp AL-2020 Specifications

General IconGeneral
BrandSharp
ModelAL-2020
CategoryAll in One Printer
LanguageEnglish

Related product manuals