E-8
WIRE CONTROLLER OPERATION
When there is failure in the unit operation, the “ERROR
will ash on the display of the wire controller and the
error code will also be displayed. When there are
multiple failures, the error codes will be displayed one
after one on the wire controller. The two digits indicate
the detailed the error code.
The Error Codes Denitions are as Follows:
Error code
E0
E1
E2
E3
E4
E5
E6
E8
E9
FF
F0
F1
F2
F3
F4
F5
EE
E5 : Material malfunction will be showed by the indicator light on the mother board of
outdoor unit.
Failure Display
Fault
Pump Failure
Compressor High Pressure Protection
Indoor Frost-Proof Protection
Compressor Low Pressure Protection
Compressor Exhaust High Temperature Protection
Compressor Overheat And Inverter Driving Protection
Communications Failure
Indoor Fan Protection
Full Water Protection
Connected control communications Failure
Failure of Indoor Room Sensor at Air Intake
Failure of Evaporator Temp. Sensor
Failure of Condenser Temp. Sensor
Failure of Outdoor Ambient Sensor
Failure of Exhaust Temp. Sensor
Failure of Indoor Room Sensor at Wire Controller
Buttons are locked (not failure)
GREE_duct_eng_1022.indd 8 08.10.27 3:32:06 PM