E-7
ENGLISH
Under normal conditions, the “ENV” and the room
temperature are displayed. Press the SLEEP button
for 5 seconds. The LCD will display “OUT ENV”. The
outdoor temperature will show in the display for 10
seconds, and then return to the room temperature.
When the unit is shut off, press the MODE button for
10 seconds to switch set values so as to decide if the
unit operating status or shut off status is memorized
after a power fail.
If the set temperature area displays "01", it means
the unit operating status or shut off status shall be
memorized after a power fail; "02" means the operating
status or shut off status will not be memorized.
Press the ON/OFF button to store the set value and
exit the setting.
Room Temperature Sensor Setting
When the unit is shut off, press the FAN button and the
SLEEP button simultaneously to activate the debug
menu.
The LCD will display “DEBUG”.
Under the debug mode, press the MODE button so
as to display “01” on the set temperature area (at the
left of “DEBUG”). The OUT ENV area (at the right of
“DEBUG”) displays setting status.
Press the (
) button or the ( ) button to select from
the following two settings:
The room temperature is measured at the air intake (The
OUT ENV area displays 01).
The room temperature is measured at the wire
controller (The OUT ENV area displays 02). The
default room temperature sensor is set at the air
intake.
Display of outdoor temperature
Memory function setting
GREE_duct_eng_1022.indd 7 08.10.27 3:32:06 PM