E-15
ENGLISH
Outdoor Unit
A B C D E
GU-X18JR
848 320 540 548 286
GU-X24JR 913 378 680 548 340
GU-X36JR 1032 412 1250 572 378
Item
Model
Precautions on installation of outdoor unit
To ensure the unit in proper function, selection of installation location must be in accordance with
following principles:
Outdoor unit shall be installed so that the air discharged by outdoor unit will not return and that
sufcient space for repair shall be provided around the machine.
The installation site must have good ventilation, so that the outdoor unit can take in and exhaust
enough air. Ensure that there is no obstacle for the air intake and exhaust of the outdoor unit. If
there is any obstacle blocking the air intake or exhaust, remove it.
Place of installation shall be strong enough to support the weight of outdoor unit, and it shall be
able to insulate noise and prevent vibration. Ensure that the wind and noise from the unit will not
affect your neighbors.
Avoid direct sunshine over the unit. It is better to set up a sun shield as the protection.
Place of installation must be able to drain the rainwater and defrosting water.
Place of installation must ensure the machine will not be buried under snow or subject to the
inuence of rubbish or oil fog.
The installation site must be at a place where the air exhaust outlet does not face strong wind.
E
C
A
D
B
length unit:mm
MIN.500
MIN.500
MIN.500
MIN.2000
MIN.500
MIN.2000
MIN.1000