Caution:
Take great care when carrying out the following connections, so as to avoid malfunction of the air-
conditioning unit because of electro magnetic interference.
•
The signal line of the wire controller must be separated from the power line and the connecting line
between the indoor unit and the outdoor unit.
•
In case the unit is installed in a place vulnerable by electro magnetic interference, it is better to use
shielded cable or double-twisted cable as the signal line of the wire controller.
Connection of signal line of wire controller
1 Open the the electric box cover of the indoor unit.
2 Pull the signal cable of the wire controller through the rubber ring.
3 Plug the signal line of the wire controller onto the 4-bit pin socket at the circuit board of the indoor
unit.
(CN10 of the wire controller connect with CN3 of the indoor unit)
4 Fix the signal cable of the wire controller with cable fastener.
Earth leakage breaker
• Provide an earth leakage breaker in order to protect against electric shock in case of leak.
• Use the current-activated, high-sensitivity, high-speed type breaker with a rated sensitivity current
of below 30mA and an operating time of below 0.1 second.
Requirement for ground
• Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe, water pipe,
lightning rod or telephone grounding wire. Incomplete grounding may cause electric shock.
• The yellow-green two-color wiring of air conditioner is grounding wire and can not be used for
other purposes. It cannot be cut off and be xed by screw, otherwise it would cause electric
shock.
Cable connecting diagram of unit
The section area of cables selected by users must not be smaller than the specications shown
diagram.
Schematic diagram of unit line connection:
GB-X18JR / GB-X24JR
GB-X36JR
POWER:
220-240V~50Hz
POWER:
220-240V~50Hz
Outdoor unit Indoor unit
main
board
main
board
1.Power cord 3G 2.5mm
2
(H07RN-F)
2.Power cord 3G 1.0mm
2
(H05W-F)
3.Communication wire
(Type:UL2835 twisted-pair)
(Size:AWG24#)
POWER:
220-240V~50Hz
POWER:
220-240V~50Hz
Outdoor unit
Indoor unit
main board
main
board
1.Power cord 3G 6.0mm
2
(H07RN-F)
2.Power cord 3G 1.0mm
2
(H05W-F)
3.Communication wire
(Type:UL2835 twisted-pair)
(Size:AWG24#)