57
LC-32LE530
LC-40LE530
STBY_ON/OFF should be low for standby on condition, please check R74.
13.2. CI Module Problem
Problem: CI is not working when CI module inserted.
Possible couses: Supply, suply control pin, detect pins, mechanical positions of pins
CI supply shoul be 5V when CI module inserted. If it is not 5V please check LED3 or PIX2
pin, this pin should be low.
Please check mechanical positions of CI module.
Detect ports should be low. If it is not low please check CI connector pins, CI module pins
and 3V3_VCC on MB61.