EasyManuals Logo

Sharp LC-52XS1E Service Manual

Sharp LC-52XS1E
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
LC-52XS1E/RU/LC-65XS1E/RU
3 – 21
7. MENU Operation [MENU BUTTON]
8. OSD Display [ON SCREEN DISPLAY]
9. Start Mode [INPUT MODE START]
10.Mode Fixed [INPUT MODE FIXED]
[9] SOFTWARE UPDATING
1. The upgrade method of monitor software
1. The software of this machine is roughly divided into the following three software.
1) Main microcomputer software
2) Monitor microcomputer software
3) LED microcomputer software
The above-mentioned microcomputer software can rewrite software by using the USB memory to have confirmed the operation.
2. Upgrade of software
[Prior preparation]
USB Memory
Selection “RESPOND” or “NO RESPOND” is selectable. (Loop is provided.)
Default RESPOND
Function The MENU keys on the main unit and R/C MENU are disabled.
Exception Regardless of the setting contents, the start operation of the process mode, inspection mode and PUBLIC_Mode is
enabled.
Regardless of the setting contents, all keys can be used while entering the process mode, inspection mode or
PUBLIC_Mode.
Key that becomes invalid
excluding Default besides
MENU Key because of
setting
ON_TIMER, Auto Preset, Manual_Memory, and clock setting.
All Direct Shift keys to the MENU display.
Remarks When set to “NO RESPOND”.
ON_TIMER is set to “OFF”.
Selection “YES” or “NO” is selectable. (Loop is provided.)
Default YES
Function When set to “NO”, the following OSD is not displayed.
Register, Setting, Adjustment MENU, Channel_Call, Volume Bar In the case of Wide Model, if the following operation is
performed, it is immediately switched (since MENU can not be displayed).
Input switching.
Keys which can be
enabled (Exquisite exam-
ple)
Brightness sensor, light control.
Keys disabled when not
set to Default (Example)
Still screen, screen display, MENU, OFF_TIMER, A V Position, Wide Mode switch, Auto Installation.
Remarks When set to “NO”.
a) The OFF_TIMER (SLEEP TIMER) setting time is cleared.
Selection “NORMAL”, “TV(*Channel)”, “INPUT1”, “INPUT2” (Loop is provided.)
Default NORMAL
Function When the power is ON, the input source or channel to start is set.
In the NORMAL mode, it follows the contents of Last_Memory.
Remarks When set to a mode other than “NORMAL”.
a) It is inhibited to display the Channel Setting MENU and to set the Channel.
b) On start with “ON_TIMER”, the set Channel of ON_TIMER is prior.
When set to “NORMAL”, “Mode Fixed (START MODE FIXED)” is set to “VARIABLE” to inhibit the selection.
When starting by "ON_TIMER", the setting Channel of ON_TIMER is priority.
Selection “VARIABLE” or “FIXED” is selectable. (Loop is provided.)
Default VARIABLE
Function When set to “FIXED”, it is disable to switch to other channel or input after start in the set value of “Start Mode (INPUT
MODE START)”.
Keys disabled when not
set to Default (Example)
Channel UP/Down, Direct_Channel Button, FLASHBACK, INPUT, STILL, Digit_Select and Direct input switching.
Remarks When “START MODE” is set to “NORMAL”, this item is disable to set. (Automatically set to “VARIABLE”.)
When set to “FIXED”.
The Channel setting MENU (Menu-setup-Auto Installation, Programme setup and Child Lock item hatching) and Input
Selection MENU in MENU are not displayed.

Other manuals for Sharp LC-52XS1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp LC-52XS1E and is the answer not in the manual?

Sharp LC-52XS1E Specifications

General IconGeneral
BrandSharp
ModelLC-52XS1E
CategoryLCD TV
LanguageEnglish

Related product manuals