MX-5001N ADJUSTMENTS 5 – 35
13-B RSPF diagonal adjustment
1) Set a test chart (A3) on the RSPF document tray, and make a
copy.
2) Measure (a) and (b) on the copied test chart. If (a) - (b) =
±1mm or more, perform the diagonal adjustment.
3) Remove the hex nut cover in the RSPF diagonal adjustment
screw section.
4) Raise the RSPF unit upright, and loosen the fixing screw of the
hinge.
5) Close the RSPF unit, and loosen the hex nut of the RSPF
diagonal adjustment screw section.
Turn the hex wrench of the RSPF skew adjustment screw to
adjust the skew.
* In the case of (A), turn the RSPF diagonal adjustment screw
counterclockwise.
In the case of (B), turn the RSPF diagonal adjustment screw
clockwise.
6) Make a copy again and measure (a) and (b) on the copied test
chart. Repeat procedures 2) to 5) until the condition ((a)-
(b)=±1mm or less) is satisfied.
7) Tighten the hinge section fixing screw which was loosened in
the procedure 4) to tighten the hinge section.
a
b
TEST CHART
A3 size
1
2
2
3
1
2
A
B