3-3
3.1.2 Space requirement 
For safety reason, Path must be considered when installing. For space, it requires: 
Its calculation is the area of the arm rotating 360 de
ree, the most outer circle and plus 1000 
mm. Different models has different dimensions. 
MODEL  The distance from the 
column center to the arm 
limit. 
Plus maintenance area 
(A) 
Total space 
requirement 
(B) 
TPR-1230  1546 mm  1000 mm  5092 mm 
TPR-1230H  1546 mm  1000 mm  5092 mm 
TPR-1600H  2087 mm  1000 mm  6174 mm 
TPR-2000H  2537 mm  1000 mm  7074 mm 
3.2 Environment requirement 
a. Never put the machine in the places where sun shines directly on it.
b.
Temperature: normal range is between +5
℃ and
 40
℃
.
c.
Humidity:    between 30% and 95%. At the max. temperature 40
℃,The relative
humidity should not be over 50%. And at the relative lower temperature, higher
humidity is acceptable I.g. at temperature 20℃,
humidity 90% is fine.
d. Please keep the machine away from gasoline, chemical substances, dust, acid, sulfides,
magnetic interference and explosive environment.
e. Please keep the machine away from the electrical interference source like welding
machine and EDM.
f. The installation ground must be flat.
g. The illumination of the work area: greater than 500lux.
h. Good ventilation.
i. Please take care there is no hydraulic splash to prevent from anyone slipping tripping
and falling in danger.