I
COPIER
TROUBLE?
57
I
I
I
I
I
I
I
MISFEED REMOVAL
Turn transport lever (E) in the direction of the arrow.
Turn roller rotating knob (D) in the direction of the
arrow to remove misfed paper.
If the misfed paper cannot be removed by turning knob (D)
alone, turn knobs (D) and (C) together.
CAUTION
Be careful not to damage the photoconductive drum or the co-
rona wires.
If the misfed paper cannot be removed in step 3, pull
out the paper transport by holding transport lever (E).
Turn roller rotating knobs (D) and (C) in the direction of
the arrows to remove the misfed paper.
If the misfed paper cannot be removed by turning roller rotating
knob (D) alone, turn roller rotating knobs (D) and (C) together.
Lift up paper guide (A) in the direction of the arrow and
remove any misfed paper.
3
4
5
6
2
(A)
Roller rotating knobs (D) (C)
Photoconductive drum
Roller rotating knobs (D) (C)
Misfeed removal