SX
Service and Maintenance Manual 3-25 960714-02B © 2007 I2407
SECTION 3 COMPONENT REPAIR
ELECTRICAL COMPONENTS
TRANSFORMERS (con’t)
1. Remove the two rear and two front screws
holding the Motor Cover on. Set screws and
Motor Cover aside (Figures 3-67 & 3-68)...
2. Locate transformer that requires replacement
(Figure 3-70).
3. If you are replacing the Seal Wire Transformer
Remove the six screws holding the Frame
Cover, set screws and Frame Cover aside
(Figure 3-70).
REPLACEMENT
Figure 3-67. Motor Cover Rear Screws
Figure 3-68. Motor Cover Front Screws
Figure 3-69. Transformer locations on an 1108 or
1109
Stepper Drive
Seal Wire
Figure 3-70. Frame Cover Screws
Always remove electrical power from the
SX
prior to performing any maintenance
on the machine.
WARNING