1 – 1
UX-108U/178U/188U
FO-375U
CHAPTER 1. GENERAL DESCRIPTION
[1] Specifications
Automatic dialing: Rapid Key Dialing: 10 numbers
Speed Dialing: 20 numbers
Fax paper: Initial starter roll (included with fax
machine): 49 ft. (10 m) roll
Recommended replacement roll:
FO-40PRw 164 ft. (50 m) roll
Automatic document feeder: 10 sheets max.
Paper cutting method: UX-108: Tear off by hand
UX-178/188/FO-375: Automatic cutter
Modem speed: 9600 bps with automatic fallback to
7200, 4800, or 2400 bps
Transmission time* : Approx. 15 seconds (Sharp special mode)
Display: 16-digit LCD display
Reception modes: Auto/Manual/Answering machine
(for connecting answering machine)
Resolution: Horizontal:
203 pels/inch (8 dots/mm)
Vertical:
Standard: 98 lines/inch
(3.85 lines/mm)
Fine/Halftone: 196 lines/inch
(7.7 lines/mm)
Super fine: 391 lines/inch
(15.4 lines/mm)
Recording system: Thermal recording
Halftone (grayscale): 64 levels
Applicable telephone line: Public switched telephone network
Compatibility: ITU-T (CCITT) G3 mode
Configuration: Half-duplex, desktop transceiver
Compression scheme: MH, MR, Sharp special mode
Scanning method: Sheet-feeder CIS (Contact Image Sensor)
Effective recording width: 8.3" (210 mm) max.
Input document size: Automatic feeding:
Width 5.8 to 8.5"
(148 to 216 mm)
Length 5.5 to 11"
(140 to 279 mm)
Manual feeding:
Width 5.8 to 8.5"
(148 to 216 mm)
Length 5.5 to 23.6"
(140 to 600 mm)
Effective scanning width: 8.3" (210 mm) max.
Contrast control: Automatic/Dark selectable
Copy function: Standard
Telephone function: Standard
(cannot be used if power fails)
Power requirements: 120 V AC, 60 Hz
Operating environment: 41 to 95°F (5 to 35°C)
Humidity: Maximum: 85 %
Power consumption: Stand-by: 5.0 W
Maximum: 100 W
Dimensions: Width: 12.1" (308 mm)
Depth: 10.4" (256 mm)
Height: 5.4" (138 mm)
Weight: UX-108:
Approx. 5.5 lbs. (2.5 kg)
UX-178/UX-188/FO-375:
Approx. 5.7 lbs. (2.6 kg)
* Based on ITU-T (CCITT) Test Chart #1 at standard resolution in Sharp
special mode, excluding time for protocol signals (i.e., ITU-T phase C
time only).
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for procduct
improvement without prior notice. The performance specifications figures indicated are nominal values of production units. There may be some
deviation from these values in individual units.