EasyManua.ls Logo

Shelly Wave Pro 1 - 11 Z-Wave Notifications Command Class; Overheat Detected

Shelly Wave Pro 1
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
11. Z-Wave Notifications Command class
11.1 Overheat detected
Comment
Overheat detected
Z-Wave Notification Type Name
Heat Alarm
Z-Wave Notification type - Value
0x04
Z-Wave Notification type - Event
State
Z-Wave Notification Name
Overheat detected
Z-Wave Notification Name - Value
0x02
Z-Wave Notification Name - Version
V2
LED signalisation
Check LED signalisation
table
Device reaction - Switch OFF all outputs and send notification
Yes
Action to restore - power cycle
Yes
Action to restore - short press on S button
Yes
Action to restore - press any switch-push button connected to any
SW (SW, SW1, SW2, …) terminal
Yes