25
It is recommended to use push buttons for this association. Supports the following command
classes:
• SWITCH_MULTILEVEL_START_LEVEL_CHANGE: initiate a transition to a new level
(increase or decrease light intensity in case of dimmer, or move shutter up or down, …)
• SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE: stop an ongoing transition (stop increase
or decrease light intensity in case of dimmer, or stop moving shutter up or down, …)
Root device - Association Group 4
Allowed nodes: 9
It is assigned to switch connected to the SW (SW2) terminal (uses Basic command class).
Triggered by SW (SW2). The device sends according to the state of SW (SW2) (switch or push-
button) the command BASIC_SET ON or BASIC_SET OFF to the associated device. This command
is reflected to the output of associated device. Supports the following command classes:
• BASIC_SET: set On / Off state at the associated device
Root device - Association Group 5
Allowed nodes: 9
It is assigned to switch connected to the SW (SW2) terminal (uses Switch Multilevel command
class). Triggered by SW (SW2).
It is recommended to use push buttons for this association. Supports the following command
classes:
• SWITCH_MULTILEVEL_START_LEVEL_CHANGE: initiate a transition to a new level
(increase or decrease light intensity in case of dimmer, or move shutter up or down, …)
• SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE: stop an ongoing transition (stop increase
or decrease light intensity in case of dimmer, or stop moving shutter up or down, …)
13. Supported load types
• Resistive (incandescent bulbs, heating devices)
• Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-
conditioners)
• Capacitive (capacitor banks, electronic equipment, motor start capacitors)