2. Introduction
2-1. Check before Use
This product has been fully inspected for quality assurance prior to shipment. Nevertheless, you are requested to
make sure that there is no error, damage or shortage of delivered items by checking the model codes, the external
view of the product, and the number of accessories.
Check the model codes affixed to the case of the product to ascertain if the respective codes designate what was
specified when you ordered it, referring to the following code table.
SR90 series is based on 3 types of selectable codes SR91, SR92, and SR93/SR94.
(1) Confirmation of Model Codes
[Example of SR91 model type codes]
SR91-8Y-90-0
N
0
1. Series SR91
2. Input 8: Universal input Thermocouple, R.T.D., Voltage (mV)
4: Current (mA), 6: Voltage (V)
3. Control output (1) Y: Contact, I: Current, P: SSR drive voltage, V: Voltage
4. Power supply 90: 100 to 240V AC, 08: 24V AC/DC
5. Event 0: None, 1: Event output
6. Option N: None
• Control output (2) Y: Contact, I: Current, P: SSR drive voltage, V: Voltage
• Heater break alarm 1: Heater break alarm (30A) 2: Heater break alarm (50A)
["1" or "2" is selectable only when control output 1 is Y or P and event
output is added]
• Analog output 3: 0 to 10mV DC, 4: 4 to 20mA DC, 6: 0 to 10V DC
• Communication 5: RS-485
• DI 8: DI (set value bias, STBY, or ACT) 1 point
7. Remarks 0: Standard, 1 to 9 / A to Z : Custom
[Example of SR92 model type codes]
SR92-8Y-N-90-0000
1. Series SR92
2. Input 8: Universal input Thermocouple, R.T.D., Voltage (mV)
4: Current (mA), 6: Voltage (V)
3. Control output (1) Y: Contact, I: Current, P: SSR drive voltage, V: Voltage
4. Control output (2) N: None, Y: Contact, I: Current, P: SSR drive voltage, V: Voltage
5. Power supply 90: 100 to 240V AC, 08: 24V AC/DC
6. Event 0: None, 1: Event output
Event output + 2: Event output + heater break alarm 30A
heater break alarm 3: Event output + heater break alarm 50A
["2" or "3" is selectable only when control output 1 is Y or P.]
7. Analog output 0: None, 3: 0 to 10mV DC, 4: 4 to 20mA DC, 6: 0 to 10V DC
8. Communication or 0: None, 5: RS-485, 7: RS-232C
DI 8: DI (set value bias, STBY, or ACT) 1 point
9. Remarks 0: Standard, 1 to 9 / A to Z : Custom
[Example of SR93/SR94 model type codes]
SR93-8Y-N-90-0000
1. Series SR93 or SR94
2. Input 8: Universal input Thermocouple, R.T.D., Voltage (mV)
4: Current (mA), 6: Voltage (V)
3. Control output (1) Y: Contact, I: Current, P: SSR drive voltage, V: Voltage
4. Control output (2) N: None, Y: Contact, I: Current, P: SSR drive voltage, V: Voltage
5. Power supply 90: 100 to 240V AC, 08: 24V AC/DC
6. Event 0: None, 1: Event output
Event output + 2: Event output + heater break alarm 30A
heater break alarm 3: Event output + heater break alarm 50A
["2" or "3" is selectable only when control output 1 is Y or P.]
7. Option 00: None
• Analog output 30: 0 to 10mV DC, 40: 4 to 20mA DC, 60: 0 to 10V DC
• DI 08: DI (set value bias, STBY, or ACT) 1 point
Analog output + 38: 0 to 10mV DC + DI (set value bias, STBY, or ACT) 1 point
DI 48: 4 to 20mA DC + DI (set value bias, STBY, or ACT) 1 point
68: 0 to 10V DC + DI (set value bias, STBY, or ACT) 1 point
• Communication 05: RS-485, 07: RS-232C
8. Remarks 0: Standard, 1 to 9 / A to Z : Custom