EasyManua.ls Logo

Shure AD600 - Troubleshooting and Event Log; Cooling Fan Settings; Troubleshooting Common Issues; Event Log Overview

Shure AD600
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Shure Incorporated
22/29
1.
2.
Cooling Fan Settings
From the Device Configuration menu: Fan
Select from the following fan setting options:
Auto: Automatically turns on to regulate the temperature
On: Runs continuously to offer maximum cooling in warm environments
Tip: View the internal temperature on the screen.
Troubleshooting
Use only one DHCP server per network.
All devices must share the same subnet mask.
All devices must have the same level of firmware revision installed.
Look for the network icons on the display of each device:
If the icon is not there, check the cable connection and the LEDs on the network jack.
If the LEDs are not on and the cable is plugged in, replace the cable and recheck the LEDs and network icon.
Use the Find All utility (Util > Network > FindAll) to view devices on the network:
The Find All report lists all devices on the network.
Check the IP address for devices not shown in the Find All report to ensure that they are on the same subnet.
To solve network issues related to Wireless Workbench, see the Networking section of the Wireless Workbench help system.
Event Log
TheeventlogrecordstheactionsoftheSpectrumManagerandthedevicesitmanages.EacheventcontainsanID,time
stamp,category,anddescriptiontohelpwithtroubleshooting.Thelogstoresupto9999events.Themostrecenteventsap
pear at the top of the log. When the storage limit is reached, the oldest events are overwritten.
Use the control wheel to scroll through events. Use the function keys to export the log or to clear the log.
Note: Log entries are not affected by power cycles.