Get Output Clip Status
Command String:
< GET x AUDIO_OUT_CLIP_INDICATOR >
Where x is ASCII channel number: 1
through 5. See table on page 1. It is
not necessary to continually send
this command. The microphone will
send a REPORT message whenev
er the status changes.
MXA310 Response:
< REP x AUDIO_OUT_CLIP_INDICATOR ON >
< REP x AUDIO_OUT_CLIP_INDICATOR OFF >
The MXA310 will respond with one
of these strings.
Flash Lights on Microphone
Command String:
< SET FLASH ON >
< SET FLASH OFF >
Send one of these commands to the
MXA310. The flash automatically
turns off after 30 seconds.
MXA310 Response:
< REP FLASH ON >
< REP FLASH OFF >
The MXA310 will respond with one
of these strings.
Turn Metering On
Command String:
< SET METER_RATE sssss >
Where sssss is the metering speed
in milliseconds. Setting sssss=0
turns metering off. Minimum setting
is 100 milliseconds. Metering is off
by default.
MXA310 Response:
< REP METER_RATE sssss >
< SAMPLE aaa bbb ccc ddd eee >
Where aaa, bbb, etc is the value of
the audio level received and is
000-060.
aaa= output 1
bbb= output 2
ccc= output 3
ddd= output 4
eee= output 5