Shure Incorporated
67/76
Port
TCP/
UDP Protocol Description
Factory De
fault
8427 udp Multcast
SLP
Required for inter-device communication Open
64000 tcp Telnet Required for Shure firmware update Open
Dante Audio & Controller
Port TCP/UDP Protocol Description
162 udp SNMP Used by Dante
[319-320]* udp PTP Dante clocking
2203 udp Custom Required for packet bridge
4321,
14336-14600
udp Dante Dante audio
[4440, 4444,
4455]*
udp Dante Dante audio routing
5353 udp mDNS Used by Dante
[8700-8706,
8800]*
udp Dante Dante Control and Monitoring
8751 udp Dante Dante Controller
16000-65536 udp Dante Used by Dante
*These ports must be open on the PC or control system to access the device through a firewall.
These protocols require multicast. Ensure multicast has been correctly configured for your network.
Important Product Information
The equipment is intended to be used in professional audio applications.
Note: This device is not intended to be connected directly to a public internet network.
EMC conformance to Environment E2: Commercial and Light Industrial. Testing is based on the use of supplied
and recommended cable types. The use of other than shielded (screened) cable types may degrade EMC perfor
mance.
Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate this
equipment.
†
†
†
†