Approach
1.
Using 6 to 8 revolutions, screw in the two M8 screws for mounting the lower end of
the explosion-proof enclosure. Make sure you leave enough space between the
screws and the flange plate for the lower end of the explosion-proof enclosure.
Figure 25: Step 1
2. Position the explosion-proof enclosure on the two screws so that the mounting
hole
s are directly over the partly-tightened screws.
Figure 26: Step 2
3. Fix the upper end of the explosion-proof enclosure to the flange plate using two
M8 scr
ews.
Figure 27: Steps 3 and 4
4. Tighten the two lower M8 screws.
5 MOUN
TING