12.6 Ambient data
The product is intended for use indoors. It is not suitable for use in special surround‐
ings (e.g., radiation and sparks from welding systems, strong sources of infrared, ther‐
mal convection, fluorescent and stroboscopic light sources, snow, rain, contamination)
or must yet be made suitable, if applicable.
Electromagnetic compati‐
bility (EMC)
Radiation emitted: Residential area (EN
61000-6-3:2007+AMD:A1:2011)
Electromagnetic immunity: Industrial environment (EN
61000-6-2:2005)
Vibration resistance Sinusoidal vibrations (resonance): 10Hz ...1000Hz (IEC
60068-2-6:2007)
Broadband noise: 10Hz ... 500Hz; 10grms, 100min/axis
(IEC 60068-2-64:2008)
Shock resistance Single shock: 30g; 6ms; 3shocks/axis Continuous shock 25g;
6ms; 500shocks/axis (IEC 60068-2-27:2008)
Ambient light immunity 3,000lx (direct exposure)
40,000lx (indirect exposure)
Altitude <2,900m above sea level
Ambient temperature,
operation
-25°C ... +50°C
Ambient temperature, stor‐
age
-40°C ... +75°C
Permissible relative
humidity
≤95%, non-condensing (EN60068-2-30:2005)
damp heat 25 ... 55% r.h. 6 cycles (EN 60068-2-30:2005)
temperature change -25 ... +50°C 10 cycles (EN 60068-2-14:2009)