EasyManua.ls Logo

SICK DT35S

SICK DT35S
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety-related response times - Slow
Device variant Response time for functions via ...
Digital output IO-Link meas‐
ured value
IO-Link status
bits (Q1/ Q2)
Analog current
output
DT35S-B15551 50ms 32ms 50ms 50ms
DT35S-B15251 25ms 16ms 25ms 25ms
Safety-related response times - Medium
Device variant Response time for functions via ...
Digital output IO-Link meas‐
ured value
IO-Link status
bits (Q1/ Q2)
Analog current
output
DT35S-B15551 25ms 16ms 25ms 50ms
DT35S-B15251 15ms 8ms 15ms 25ms
12.4 Performance
Device variant DT35S-B15251 DT35S-B15551
Measuring object Natural objects
Resolution 1mm
Repeatability 5mm (1σ)
Accuracy Typ. ±10mm
Temperature response of 0.5mm/K
Light sender Laser, red
Visible red light
Max. power ≤250mW, pulse
duration 4ns, wavelength:
658nm, pulse rate: 1/250
Laser, red
Visible red light
Max. power ≤250mW, pulse
duration 4ns, wavelength:
658nm, pulse rate: 1/500
Laser class 2 (IEC 60825-1:2014, EN
60825-1:2014)
1 (IEC 60825-1:2014, EN
60825-1:2014)
Typ. light spot size (dis‐
tance)
15mm x 15mm at 2m
12.5 Interfaces
IO-Link IO-Link V1.1, COM2 (38.4kBaud)
Function: Process data
Digital output Quantity: 1 … 2
1)
,
2)
Type: Push-pull: PNP/NPN
Function: Q2 output switchable: current output/ digital output
Maximum output current I
A
: ≤ 100mA
Analog output Quantity: 1
Type: Current output
Current: 4mA ... 20mA, ≤ 450Ω
Resolution: 12bit
Multifunctional input (MF) Quantity: 1
3)
Optical displays 2 LEDs (operational status, status of digital outputs)
1)
Output Q, short-circuit protected
2)
Voltage drop < 3 V
3)
Response time ≤ 60 ms
12 TECHNICAL DATA
60
O P E R A T I N G I N S T R U C T I O N S | DT35S 8027663//2022-08-04 | SICK
Subject to change without notice

Table of Contents