Safety-related response times - Slow
Device variant Response time for functions via ...
Digital output IO-Link meas‐
ured value
IO-Link status
bits (Q1/ Q2)
Analog current
output
DT35S-B15551 ≤50ms ≤32ms ≤50ms ≤50ms
DT35S-B15251 ≤25ms ≤16ms ≤25ms ≤25ms
Safety-related response times - Medium
Device variant Response time for functions via ...
Digital output IO-Link meas‐
ured value
IO-Link status
bits (Q1/ Q2)
Analog current
output
DT35S-B15551 ≤25ms ≤16ms ≤25ms ≤50ms
DT35S-B15251 ≤15ms ≤8ms ≤15ms ≤25ms
12.4 Performance
Device variant DT35S-B15251 DT35S-B15551
Measuring object Natural objects
Resolution 1mm
Repeatability 5mm (1σ)
Accuracy Typ. ±10mm
Temperature response of 0.5mm/K
Light sender Laser, red
Visible red light
Max. power ≤250mW, pulse
duration 4ns, wavelength:
658nm, pulse rate: 1/250
Laser, red
Visible red light
Max. power ≤250mW, pulse
duration 4ns, wavelength:
658nm, pulse rate: 1/500
Laser class 2 (IEC 60825-1:2014, EN
60825-1:2014)
1 (IEC 60825-1:2014, EN
60825-1:2014)
Typ. light spot size (dis‐
tance)
15mm x 15mm at 2m
12.5 Interfaces
IO-Link IO-Link V1.1, COM2 (38.4kBaud)
Function: Process data
Digital output Quantity: 1 … 2
1)
,
2)
Type: Push-pull: PNP/NPN
Function: Q2 output switchable: current output/ digital output
Maximum output current I
A
: ≤ 100mA
Analog output Quantity: 1
Type: Current output
Current: 4mA ... 20mA, ≤ 450Ω
Resolution: 12bit
Multifunctional input (MF) Quantity: 1
3)
Optical displays 2 LEDs (operational status, status of digital outputs)
1)
Output Q, short-circuit protected
2)
Voltage drop < 3 V
3)
Response time ≤ 60 ms
12 TECHNICAL DATA
60
O P E R A T I N G I N S T R U C T I O N S | DT35S 8027663//2022-08-04 | SICK
Subject to change without notice